关注新加坡天然气置换工程,了解燃气灶具产品的评估要求

尊敬的客户:

天然气气源将作为当前的气体供应在新加坡使用. EMA暂未最终决定是否将城镇气管网系统转换为天然气输送管网系统. 但是, EMA不反对采用EN437和E类气种(最大压力26mbar)用于天然气在新加坡使用.

为了确保将来燃气灶具能够使用天然气, 需要出口新加坡市场的产品供应商可以现在开始向Intertek申请包括天然气, 城镇气和液化气的测试.

对现有已经过EN30-1-1测试的注册的燃气灶具, 基于天然气的如下测试需要被重新评估:

6.1.2 Obtaining the input rates This test is required if gas hob was previously tested to town gas and/or LPG
6.1.3 Flame supervision devices This test is applicable if the gas hob is fitted with flame failure device and was tested to and registered based on EN 30-1-1: 1998. Compulsory if the gas hob was tested to and registered based on EN 30-1-1: 2008
6.1.5 Heating These tests are required if the nominal heat input obtained for Natural Gas (NG) are the highest between :
- NG and Town Gas ;
- NG and LPG or
- NG, LPG and Town Gas
and exceeded 10%
5.1.4.3 Hotplate pan supports
6.1.7 Total input of the appliance This test is required if gas hob was previously tested to LPG only
6.2.1 Ignition, cross-lighting and flame stability for hotplates This test is required if gas hob was previously tested to town gas and/or LPG
6.3.1 Ignition, cross-lighting and flame stability for ovens grills This test is required if gas hob was previously tested to town gas and/or LPG
6.2.2 Combustion This test is required if gas hob was previously tested to town gas and/or LPG

如对标准内容有任何疑问及咨询请联系您身边的Intertek专家!