Overview of Toothbrush and other Oral Care Products for Global Market
 

Intertek toothbrush and oral care products testing service including mechanical, materials, reliability, safety and chemical related tests. Based on national regulation, standard, and CE certification requirement, to provide comprehensive and professional testing services for all kinds of manual toothbrushes, electric toothbrushes, dental floss, interdental brushes, oral irrigators, antibacterial toothbrushes and other products, with testing capabilities covering major markets such as the United States of America (US), Europe Union (EU) and China.

US Market

Products Standard Main Testing Items
Manual toothbrushes ANSI/ADA Standard
No.119-2021
ISO 20126:2022
Physical inspection, Tuft retention, Handle impact strength, Fatigue resistance, Fatigue resistance after chemical challenge
Powered toothbrushes ANSI ADA Standard
No.120-2009 (R2014)
ISO 20127: 2020
Physical inspection, Electrical safety, Tuft retention, Mechanical strength, Resistance to chemical challenge
Dental floss ISO 28158: 2018 Material and Shape, Strength
Manual interdental brushes ANSI/ADA Standard No.125-2018 (R2022)
ISO 16409: 2016
Defects or Contamination, Brush size, Filament retention, Stem retention, Stem durability

EU Market

Products Standard Main Testing Items
Manual toothbrushes EN ISO 20126:2022 Physical inspection, Tuft retention, Handle impact strength, Fatigue resistance, Fatigue resistance after chemical challenge, Filament end-rounding
Powered toothbrushes EN ISO 20127: 2020 Physical inspection, Electrical safety, Tuft retention, Mechanical strength, Resistance to chemical degradation
Dental floss EN ISO 28158: 2018 Material and Shape, Strength
Manual interdental brushes EN ISO 16409: 2016 Defects or Contamination, Brush size, Filament retention, Stem retention, Stem durability
Flush type Dental Irrigator/ Water Flosser/ Oral Irrigator EN 60335-1 +
EN 60335-2-52
Electrical safety
Manual toothbrushes
Powered toothbrushes
EN ISO 22254:2005 Tuft deflection force

China Market

Products Standard Main Testing Items
Manual toothbrushes for adult GB 19342-2013 +
GB 39669-2020
Hygienic requirements, Safety requirements, Specification, Tuft stiffness, Tuft retention, Shank bending-resistant, Neck bending-resistant, Hot water resistance, Filament flexure recovery rate, Filament end-rounding, Physical inspection
Manual toothbrushes with tapered filament GB 30003-2013 +
GB 39669-2020
Hygienic requirements, Safety requirements, Specification, Tuft stiffness, Tapered filament、Non-tapered filament, Tuft retention, Shank bending-resistant, Neck bending-resistant, Hot water resistance, Filament flexure recovery rate, Filament end-rounding, Physical inspection
Manual toothbrushes for children GB 30002-2013 +
GB 39669-2020
Hygienic requirements, Safety requirements, Specification, Tuft stiffness, Tuft retention, Shank bending-resistant, Neck bending-resistant, Hot water resistance, Filament flexure recovery rate, Filament end-rounding, Decorative parts, Physical inspection
Manual Antibacterial toothbrush GB/T 36391 - 2018 +
GB 39669-2020
Safety, Antibacterial property, Hygienic requirements、Specification、Tuft stiffness, Physical property、Tapered filament、Non-tapered filament and Physical inspection should comply with standards GB 19342-2013、GB 30002-2013、GB 30003-2013’s requirement.
Powered Antibacterial toothbrush GB/T 36391 -2018 +
GB 39669-2020
Safety, Antibacterial property, Physical inspection, Specification, Hygienic requirements, Tuft stiffness, Filament end-rounding, Tuft retention, Hot water resistance, Filament flexure recovery rate, Detachable brush head firmness, Switch cycle test, Noise level

Powered toothbrush

GB/T 40362-2021 +
GB 39669-2020
Physical inspection, Specification, Brush head tot water resistance, Filament flexure recovery rate, Detachable brush head firmness, Switch cycle test, Noise level
Dental floss QB/T 4748-2014 +
GB 39669-2020
Raw material, Hygienic requirements, Workmanship and staining test, Dental floss loading test, Net quantity, Packaging quality
Dental floss stick QB/T 4749-2014 +
GB 39669-2020
Raw material, Hygienic requirements, Dental floss stick loading test, Net quantity, Packaging quality
Manual interdental brushes GB/T 36992-2019 +
GB 39669-2020
Chemical Safety, Hygienic requirements, Brush size, Filament retention, Stem retention, Stem durability, Hot water resistance, Physical inspection
Flush type Dental Irrigator/ Water Flosser/ Oral Irrigator GB 39669-2020

Phthalate plasticizers,Hazardous substances,tapered filament pH,Sulfur dioxide leaching in wooden toothpicks and bamboo toothpicks,Tuft retention, Neck bending-resistant, brush head for children’s toothbrush, Filament end-rounding, Tapered filament, Electrical safety, Bristle block firmness for powered toothbrush, Resistance to chemical degradation for powered toothbrush, Detachable parts for children's toothbrushes, Sharp edge and sharp points, Decorative parts for Children’s toothbrush and oral implements