Intertek toothbrush and oral care products testing service including mechanical, materials, reliability, safety and chemical related tests. Based on national regulation, standard, and CE certification requirement, to provide comprehensive and professional testing services for all kinds of manual toothbrushes, electric toothbrushes, dental floss, interdental brushes, oral irrigators, antibacterial toothbrushes and other products, with testing capabilities covering major markets such as the United States of America (US), Europe Union (EU) and China.
US Market
| Products |
Standard |
Main Testing Items |
| Manual toothbrushes |
ANSI/ADA Standard No.119-2021 ISO 20126:2022 |
Physical inspection, Tuft retention, Handle impact strength, Fatigue resistance, Fatigue resistance after chemical challenge |
| Powered toothbrushes |
ANSI ADA Standard No.120-2009 (R2014) ISO 20127: 2020 |
Physical inspection, Electrical safety, Tuft retention, Mechanical strength, Resistance to chemical challenge |
| Dental floss |
ISO 28158: 2018 |
Material and Shape, Strength |
| Manual interdental brushes |
ANSI/ADA Standard No.125-2018 (R2022) ISO 16409: 2016 |
Defects or Contamination, Brush size, Filament retention, Stem retention, Stem durability |
EU Market
| Products |
Standard |
Main Testing Items |
| Manual toothbrushes |
EN ISO 20126:2022 |
Physical inspection, Tuft retention, Handle impact strength, Fatigue resistance, Fatigue resistance after chemical challenge, Filament end-rounding |
| Powered toothbrushes |
EN ISO 20127: 2020 |
Physical inspection, Electrical safety, Tuft retention, Mechanical strength, Resistance to chemical degradation |
| Dental floss |
EN ISO 28158: 2018 |
Material and Shape, Strength |
| Manual interdental brushes |
EN ISO 16409: 2016 |
Defects or Contamination, Brush size, Filament retention, Stem retention, Stem durability |
| Flush type Dental Irrigator/ Water Flosser/ Oral Irrigator |
EN 60335-1 + EN 60335-2-52 |
Electrical safety |
Manual toothbrushes Powered toothbrushes |
EN ISO 22254:2005 |
Tuft deflection force |
China Market
| Products |
Standard |
Main Testing Items |
| Manual toothbrushes for adult |
GB 19342-2013 + GB 39669-2020 |
Hygienic requirements, Safety requirements, Specification, Tuft stiffness, Tuft retention, Shank bending-resistant, Neck bending-resistant, Hot water resistance, Filament flexure recovery rate, Filament end-rounding, Physical inspection |
| Manual toothbrushes with tapered filament |
GB 30003-2013 + GB 39669-2020 |
Hygienic requirements, Safety requirements, Specification, Tuft stiffness, Tapered filament、Non-tapered filament, Tuft retention, Shank bending-resistant, Neck bending-resistant, Hot water resistance, Filament flexure recovery rate, Filament end-rounding, Physical inspection |
| Manual toothbrushes for children |
GB 30002-2013 + GB 39669-2020 |
Hygienic requirements, Safety requirements, Specification, Tuft stiffness, Tuft retention, Shank bending-resistant, Neck bending-resistant, Hot water resistance, Filament flexure recovery rate, Filament end-rounding, Decorative parts, Physical inspection |
| Manual Antibacterial toothbrush |
GB/T 36391 - 2018 + GB 39669-2020 |
Safety, Antibacterial property, Hygienic requirements、Specification、Tuft stiffness, Physical property、Tapered filament、Non-tapered filament and Physical inspection should comply with standards GB 19342-2013、GB 30002-2013、GB 30003-2013’s requirement. |
| Powered Antibacterial toothbrush |
GB/T 36391 -2018 + GB 39669-2020 |
Safety, Antibacterial property, Physical inspection, Specification, Hygienic requirements, Tuft stiffness, Filament end-rounding, Tuft retention, Hot water resistance, Filament flexure recovery rate, Detachable brush head firmness, Switch cycle test, Noise level |
|
Powered toothbrush
|
GB/T 40362-2021 + GB 39669-2020 |
Physical inspection, Specification, Brush head tot water resistance, Filament flexure recovery rate, Detachable brush head firmness, Switch cycle test, Noise level |
| Dental floss |
QB/T 4748-2014 + GB 39669-2020 |
Raw material, Hygienic requirements, Workmanship and staining test, Dental floss loading test, Net quantity, Packaging quality |
| Dental floss stick |
QB/T 4749-2014 + GB 39669-2020 |
Raw material, Hygienic requirements, Dental floss stick loading test, Net quantity, Packaging quality |
| Manual interdental brushes |
GB/T 36992-2019 + GB 39669-2020 |
Chemical Safety, Hygienic requirements, Brush size, Filament retention, Stem retention, Stem durability, Hot water resistance, Physical inspection |
| Flush type Dental Irrigator/ Water Flosser/ Oral Irrigator |
GB 39669-2020 |
Phthalate plasticizers,Hazardous substances,tapered filament pH,Sulfur dioxide leaching in wooden toothpicks and bamboo toothpicks,Tuft retention, Neck bending-resistant, brush head for children’s toothbrush, Filament end-rounding, Tapered filament, Electrical safety, Bristle block firmness for powered toothbrush, Resistance to chemical degradation for powered toothbrush, Detachable parts for children's toothbrushes, Sharp edge and sharp points, Decorative parts for Children’s toothbrush and oral implements
|